OUTPUT VOLTAGES:
0 to 5 volts at 5 amps, 0 to 30 volts at 2 amps and 0 to ±15 volts dual
tracking at 500 milliamps.
All
output voltages are continuously adjustable by front panel controls and
are simultaneously available.
Output voltages are displayed on 3 ½ digit meter with accuracy of ±0.5%±2
least counts. Meter has LED display of 12.5 mm height. Front panel
selection switch provides display of any of the output voltages or
any unknown external voltage from 0 to ±199.9 volts DC with resolution of
0.1 volts.
Output voltages can be floated on any live voltage or any of the terminals
of the output voltages can be grounded to get positive or negative
voltages.
PROTECTION:
Short circuit and overload protected. Constant voltage constant current
type of regulation provides constant voltage if load current is less than
the maximum current capacity. If load tries to draw more current than the
capacity, current becomes constant at full capacity and output voltage
comes down
to limit the current at its full capacity.
REGULATION:
±0.05% for no load to full load and for ±10% variation in mains voltage.
RIPPLES:
Less than 3 milli volt r.m.s.
POWER REQUIREMENTS:
230±10% volts AC, 50/60 Hertz. Power consumption is 1.5 times the sum of
4 multiples of maximum
voltage rating of each output to its actual load current. (Option of
operation on 110 ±10% volts AC,
50/60 Hertz is available at extra charge of 10% and delivery period of 3 to
4 weeks).
SIZE AND WEIGHT:
135 mm (H)
X 365 mm (W) X 270 mm (D). 9 kgs.
STANDARD ACCESSORIES:
3 pairs of test leads and instruction manual.
|