PANEL METERS
(MOVING COIL TYPE FOR DC V AND I MEASUREMENTS)
(MOVING COIL TYPE FOR AC V AND I MEASUREMENTS)

 

SO65/MO65/SO85/MO85

SR65/MR65/SR85/MR85/MR100

SR96/MR96

FOR AC V AND I MEASUREMENTS :

Choices of any 1 of ranges of 10 mA, 25 mA, 30 mA, 50 mA, 100 mA, 250 mA, 300 mA, 500 mA, 1 A, 2 A, 5 A, 10 A, 15 A, 20 A, 25 A, 30 A, CT
operated for higher currents, 10 V,20 V, 30 V, 50 V, 60 V, 75 V, 100 V, 150 V, 300 V, 500 V and 600 V AC.

Sturdy movement with zero adjustment from front.

Fluid damping to ensure dead beat movement.

5V A burden.

45 to 55 Hertz.

Spade or knife edge pointer with non linear scale.

Flush mounting.

FOR DC V AND I AND TEMPERATURE MEASUREMENTS AND GALVANOMETERS :

Choices of any 1 of ranges of 1 mA, 2 mA, 5 mA, 10 mA, 25 mA, 30 mA, 50 mA, 100 mA, 250 mA, 300 mA, 500mA, 1 A, 2 A, 5 A, 10 A, 15 A, 20 A,
25 A, 30 A, shunt operated for higher currents, 50 mV, 60 mV, 75 mV, 100 mV, 250 mV, 500 mV, 1V, 2 V, 5 V, 10 V, 15 V, 20 V, 25 V, 30 V, 50 V,
75 V, 100 V, 150 V, 300 V, 500 V, 600 V, galvanometers of 30-0-30G and 50-0-50G (sensitivity of 500-0-500µ A), 200° C (type J-Fe/con), 400° C
(type J-Fe/con), 600° C (type J-Fe/con), 800° C (type K-Cr/AI), 1000° C (type K-Cr/AI), 1200° C (type K-Cr/AI) and 1600° C (type S-pt/pt-Rh 10%). 

Sturdy movement with zero adjustment from front.  

Meter sensitivity 1000 ohms per volt for voltmeters. 75 mV drop for ammeters.  

Spade or knife edge pointer with linear scale.  

Alnico high flux density magnets.  

Flush mounting.

Shape

ROUND

RECTANGULAR

SQUARE

Model no. for AC meters

SO 65

SO 85

SR 65

SR 85

--

SR 96

Model no. for DC meters

MO 65

MO 85

MR 65

MR 85

MR 100

MR 96

Over-all size

83mm dia

108mm dia

85mm (W) x 70mm (H)

110mm (W) x 86mm (H)

117mm (W) x 100mm (H)

96mm (W) x 96mm (H)

Panel cutout size

66mm dia

86mm dia

66mm dia

66mm dia

66mm dia

92mm (W) x 92mm (H)

Mounting details

3 holes of 4mm on 75 pcd

3 holes of 5mm at 96.5 pcd

4 holes of 3mm at 63.5mm x 49.5mm

4 holes of 3mm at 97mm x 73mm

4 holes of 4mm at 112mm x 90mm

Rear mounting bracket is provided.

Inside depth

30mm

57.5mm

39mm

22mm

35.5mm

72mm

Scale length

48.5mm

67mm

59mm

72mm

93mm

98mm

Case material

Bakelite

Bakelite

ABS

Bakelite

Bakelite

ABS

Accuracy

± 2.5%

± 2.5%

± 2.5%

± 1.5%

± 1.5%

± 1.5%

Price for AC
meters
(Rs.)

220/-

250/-

250/-

300/-

350/-

250/-

Price for DC meters (Rs.)

300/-

350/-

350/-

400/-

450/-

370/-

Price for frequency meter(Rs.)

-

-

-

-

-

500/-

Insulation Resistance: More than 20 mega ohms between terminals and casing at 500V DC.
High Voltage Breakdown: Capable of withstanding 2.5 KV r.m.s for one minute between terminal and casing.
Damping Time: Less than 4 seconds for pointier to come to within 1.5% of its steady state value when signal of 2/3 rd of full scale value is applied.